Siphon
Once the tube is full, the longer column of water on the outlet side outweighs the column climbing from the tank, and the air pressure on the tank surface pushes the water up and over. The flow keeps going until the surface falls to the outlet's level.
The physics
- Speed (Bernoulli from the still surface to the outlet): v = √(2 g h), where h is how far the outlet is below the surface. Flow = v × tube area.
- Pressure at the crest: p = patm − ρ g z − ½ ρ v², where z is the crest's height above the surface. It can't go below zero, so with no flow the crest can be at most patm ÷ (ρ g) ≈ 10.3 m above the surface, and less in practice because water starts to boil at very low pressure.
Ideal flow: friction in a real tube lowers the speed, most in long or narrow tubes. Standard atmosphere 101.325 kPa. Tested: the crest pressure and the height limit (packages/mechanics/test/fluids.test.ts).
Example
With outlet below the surface 1 m, crest above the surface 2 m, tube bore 12 mm: exit speed: 4.43 m/s; flow: 30.1 L/min; pressure at the crest: 71.9 kPa absolute; highest crest that works: 9.33 m. Open this setup, then change one thing at a time.
Related: Tank drain time · Venturi meter · Water pressure at depth